电源线

Globtek推出了全新的电源线搜索工具,界面友好,规格齐全,易于搜索。你可以通过选择插头类型,线材类型,线芯数量,电气标准,电压或最大电流来快速查找所需线材规格。



Request Info Input Cord Options

Standard stock power cords

3 Conductors (Grounded) IEC 320/C13
Part Number/ LinkCountryPlugTerminationLength (mm)Length (ft)RFQDistributor stock (Click to order)
705-701-KIT(R)International Cord with changeable plugs Kit180 Degree US, UK, Europe, Australia/NZIEC 320/C1321507
7055002M5701A-KIT(R)International Cord with changeable plugs KitDown Angle US, UK, Europe, Australia/NZIEC 320/C1321507
3021457F701(R)N. American (Type B)NEMA 5-15PIEC 320/C1321507
1191068F0701(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C1324598
2194272M5701-T(R)Argentina (Type I)IRAM 2073IEC 320/C1325008
5502022M5701A(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C1325008
204B4272M5701(R)Brazil (Type N)BRAZILIEC 320/C1325008
6023602M5701(R)China (Type I)CCC GR2099IEC 320/C1325008
G8014272M5701(R)Danish (Type K)AFSNIT SECTION 107-2-D1IEC 320/C1325008
23144272M5701-T(R)Europe (Type E)CEE 7/7IEC 320/C1325008
23134272M5701EUKR(R)Europe/Korea Combo (Type E)CEE 7/7 / KSC8305IEC 320/C1325008
205IN4272M5701(R)               India (Type D)India IS 1293 (also known as IA16A3 or BS546)IEC 320/C1325008
208IN4272M5701(R)India (Type M)India IS 1293 (also known as IA16A3 or BS546)IEC320/C1325008
377C4272M5701(R)Israel (Type H)ISL 377CIEC 320/C1325008
23024272M5701(R)Italy (Type L)CEI 23-16/VIIIEC 320/C1325008
3003339F701(R)
[3x1.25mm2]

3003068F2701-HK(R) 
[3 x 2.0mm2]
Japan (Type B)JIS 8303 / 3 PINSIEC 320/C1325008

302J115J6F0701J(R)North America / Japan (Type B – 12A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved)IEC 320/C1318306
302J104J6F0701J(R)North America / Japan (Type B – 15A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved)IEC 320/C1318306
302JT104J9F0701JT(R)North America / Japan / Taiwan (Type B – 15A)NEMA 5-15P (cULus approved), Japan JIS C 8303 (PSE Approved), Taiwan CNS 6797 (BSMI Approved)IEC 320/C1328009
2313K3432M5701(R)Korea (Type F)KS C 8305IEC 320/C1325008
5804272M5701(R)Russia (Type F)GOST 7396IEC 320/C1325008
2084272M5701(R)South Africa (Type M)South Africa SABS164-1 (16A type)IEC 320/C1325008
23214272M5701(R)Switzerland (Type J)SEV 1011IEC 320/C1325008
3003322M5701(R)Taiwan (Type B)BSMIIEC 320/C1325008
6363762M5701(R)Thailand (Type O)TIS 166-2549IEC 320/C1325008
PZ0800100-2M5BK13H(RUK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS 1363AIEC 320/C1325008
7055002M5701A(R)InternationalIEC 320 C14-C13IEC 320/C1325008
3 Conductors (Grounded) IEC 320/C5 (Mickey Mouse)
Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)RFQDistributor stock (Click to order)
705-712-KIT(R)International Cord with changeable plugs Kit180 Degree US, UK, Europe, Australia/NZIEC 320/C518806
705-712-KIT6(R)International Cord with changeable plugs Kit180 Degree US, UK, Europe, Australia/NZIEC 320/C518806
3021066F712(R)N. American (Type B)NEMA 5-15PIEC 320/C518806
1191068F0712(R)N. American (Type B)NEMA 5-15P HospitalIEC 320/C524598
2194262M0712(R)Argentina (Type I)IRAM 2073IEC320/C520506.7
2064262M0712(R)Australian (Type I)AS3112 / 3 PRONGIEC 320/C520006.6
204B4262M0712(R)Brazil (Type N)BRAZILIEC 320/C520006.6
6023592M5712(R)China (Type I)CCC GR2099IEC 320/C525008
23144262M0712(R)Europe (Type E)CEE 7/7IEC 320/C520506.6
2313K3432M0712(R)Korea (Type F)KS C 8305IEC 320/C520006.6
205IN4262M0712(R)India (Type D)India IS 1293 (also known as IA16A3 or BS546)IEC320/C520006.6
377C4262M0712(R)Israel (Type H)ISL 377CIEC320/C520506.7
23024262M0712(R)Italy (Type L)CEI 23-16/VIIIEC 320/C520006.6
3003316F0712(R)Japan (Type B)JIS 8303 / 3 PINSIEC 320/C518306
3021066F0712ULPSE(R)Japan / USA (Type B)JIS 8303 / 3 PINS + NEMA 5-15PIEC 320/C518306
2054262M0712(R)S. Africa (Type D)South Africa SABS164-1   (6A type plug)IEC320/C520506.7
2084262M0712(R)S.Africa (Type M)South Africa SABS164-1 (16A type plug)IEC 320/C520006.6
23214262M0712(R)Switzerland (Type J)SEV 1011 ( EL 203)IEC 320/C520006.6
3003316F0712(R)Taiwan (Type B)BSMIIEC 320/C520006.6
6104262M0712(R)UK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS1363IEC 320/C520006.6
2 Conductors (No Ground) IEC 320/C7 (Figure "8")
Part Number / LinkCountryPlugConnectorLength (mm)Length (ft)RFQDistributor stock (Click to order)
CC8-703-KIT(R)International Cord with changeable plugs Kit180 Degree US, UK, Europe, Australia/NZIEC 320/C720007
2094112M703(R)Argentina (Type I)IRAM 2063IEC 320/C720007
5014112M703A(R)Australian (Type I)AS 3112IEC 320/C720007
207B4111M8703(R)Brazil (Type N)NBR14136IEC 320/C718006
4533501M8703(R)China (Type A)GB 2099.1IEC 320/C718306
2074112M703A(R)European (Type C)CEE 7/16IEC 320/C720007
2084111M8703(R)South Africa (Type M)BS 546IEC 320/C718006
2084111M8703B(R)India (Type M)INDIA ISI:1293IEC 320/C718006
2714111M8703A(R)India (Type C)IS:1293IEC 320/C718006
451J3401M8703(R)Japan (Type A)JIS 8303IEC 320/C718306
2044112M703A(R)Korea (Type C)KS C8305IEC 320/C720007
4511116F703A(R)N. American (Type A)NEMA 1-15PIEC 320/C718306
4033401M8703A(R)Taiwan (Type A)CNS690IEC 320/C718306
6104112M703A(R)UK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS1363IEC 320/C720007
451G1116F703A(R)Gulf States (Kuwait, Bahrain, Oman, Qatar, Saudi Arabia, Yemen and the United Arab Emirates (UAE) (Type A)Nema 1-15PIEC 320/C718306
2074112M703AEUSA(R)European/South Africa Combo(Type C)CEE 7/16IEC 320/C720007
6303742M5703(R)Thailand (Type C)TIS 166-2549IEC 320/C725008
2 Conductors (No Ground) IEC 320/C17
209A4062M071(R)Argentina (Type I)IRAM 2063IEC320/C1720006.6
5014112M071A(R)Australia (Type I) AS3112IEC 320/C1720006
204B4062M071(R)Brazil (Type N)NRR 14136IEC320/C1720006.6
4533502M071A(R)China (Type A)GB 2099.1IEC320/C1720006.6
2074232M071C(R)Europe (2.5A, Type C)CEE 7/7IEC 320/C1720006.6
489C4232M071A(R)Europe (10A)CEE 7/17IEC320/C1720006.6
208A41111M8071A(R)India (Type D) IS 1293 IEC 320/C1718006
451J3322M071A(R)Japan (Type A)JIS 8303IEC320/C1720006.6
401P1086F071A(R)North America (Type A)NEMA 1-15PIEC 320/C1718286
401P1086F071CNorth America (Type A)NEMA 1-15PIEC 320/C1718286
401P1219F71ANorth America (Type A)NEMA 1-15PIEC 320/C1727439
4033321M8071(R)Taiwan (Type A)CNS10917IEC 320/C1718006
6104232M071A(R)UK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS1363 (Fuse 3A)IEC 320/C1720006.6
6303742M571A(R)Thailand (Type C)TIS 166-2549IEC 320/C1725008
3 Conductors (Grounded) IEC60320 C19
5502022M57032(R)Australian (Type I) AS/NZS 3112IEC60320 C1925008

6023602M57032(R)China (Type I)China GB 1002 IEC60320 C1925008

23144282M57032(R)Europe (Type C)CEE 7/7 plugIEC60320 C1925008

2084272M57032(R)India (Type D)BIS IS 1293:2005IEC60320 C1925008

70335148F07032(R)InternationalIEC 60320 C20IEC60320 C1924388

377C4282M57032(R)Israel (Type H) SI 32 (Type H)IEC60320 C1925008

3003062M57032(R)Japan (Type B)NEMA 5-15P Hospital GradeIEC60320 C1925008

703310416F47032(R)N. AmericaIEC 60320 C20IEC60320 C19487616

3201368F7032(R)N. AmericanNema 5-20PIEC60320 C1924388

3191368F7032(R)N. AmericanNema L5-20IEC60320 C1924388

3601368F27032(R)N. AmericanNema 6-20PIEC60320 C1924388

3611048F27032(R)N. AmericanNEMA 6-15PIEC60320 C1924388

37512312F7032L(R)N. AmericanNema 5-20PIEC60320 C19366012

11910410F7032(R)N. American (Type B)NEMA 5-15P HospitalIEC60320 C19304810

11910416F7032(R)N. American (Type B)NEMA 5-15P HospitalIEC60320 C19500016

3021058F27032(R)N. American (Type B)NEMA 5-15PIEC60320 C1925008'2"

3021239F07032L(R)N. American (Type B)NEMA 5-15PIEC60320 C1927438.2

23211272M57032(R)Switzerland (Type J)SEV 6534-2 (Type J)IEC60320 C1925008

6363772M57032(R)Thailand (Type O)TIS 166-2549IEC60320 C1925008
6104282M57032(R)UK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS1363A plugIEC60320 C1925008

6104283M07032(R)UK, Hong Kong, Singapore, Gulf States, Malaysia, Saudi Arabia (Type G)BS1363A plugIEC60320 C1930009.8

Custom Power Cords

UL2468

End Cut

UL2468 END CUT

Wire is cut even at customer specified length.

Wire Slit

UL2468 WIRE SLIT

Where parallel wire is used, ends can be separated from each other to customer specifications.

Wire Strip

UL2468 WIRE STRIP

Wire ends are “stripped” of their insulation material to expose the inner copper strands.

Cutback

UL2468 CUTBACK

Wires are cut and terminated at different lengths according to customer specifications.

Partial strip

UL2468 PARTIAL STRIP

UL1185

Blunt Cut

UL1185

Cable is cut even at customer specified length.

Remove Outer Jacket

UL1185

Also known as R.O.J., the outer insulating cable jacket is removed to expose the inner wires. Length is determined by customer.

ROJ & Stripped Wires

UL1185

Outer cable jacket is removed and wire ends are stripped of insulating material.

Cutback Wires

UL1185

Outer cable jacket is removed and wires are cut and terminated at different lengths.

Partial strip

UL1185

UL2464

Blunt Cut

UL2464

Cable is cut even at customer specified length.

Remove Outer Jacket

UL2464

Also known as R.O.J., the outer insulating cable jacket is removed to expose the inner wires. Length is determined by customer.

ROJ & Stripped Wires

UL2464

Outer cable jacket is removed and wire ends are stripped of insulating material.

Cutback Wires

UL2464

Outer cable jacket is removed and wires are cut and terminated at different lengths.

Partial strip

UL2464

Terminals

Quick Connect

TERMINALS

Available In: Un-Insulated, Pre-Insulated, Fully-Insulated, Right-Angle (Flag)

Ring Terminal

TERMINALS

Used to attach product with screw or bolt. Perfect for a ground connection. Also available in locking.

Spade or Fork Terminal

TERMINALS

Similar to a Ring Terminal, but removable without completely unscrewing bolt or screw.

Ferrule Terminal

TERMINALS

For use with Terminal Blocks. Used to crimp and secure bare copper strands. Also available in a double for crimping 2 separate wires.

Quick reference for common terms used in reference to Power Supply Cords

AWG
 Abbreviation for American Wire Gauge.

Alternating Current (A-C) The charge flow of a current periodically and regularly reverses in a cyclic manner.

Ampere (A) Unit that expresses rate of flow of an electrical current. One ampere is the current flowing through one OHM of resistance at one volt potential.

CEE International Color Code. See Inner Conductor Colors.

CSA Canadian Standards Association. This is a nonprofit, independent organization that operates a listing service for electrical materials and equipment in the Canadian counterpart of the Underwriters Laboratories.

HPN Parallel Heater Cord, typically Neoprene-insulated two conductor.

Hypot A test designed to determine the highest potential that can be applied to a conductor without breaking through the insulation.

ICC International Color Code on the inner conductors (blue, brown, green with yellow stripe). See Inner Conductor Colors.

IEC International Electromechanical Commission. A European group consisting of multi-national representatives which develop standards for electrical components. See IEC-320 Standardized Appliance Connectors.

Inner Conductor Colors

FunctionNorth American (NA)International (ICC)
HotBlackBrown
NeutralWhiteBlue
Earth (Ground)GreenGreen w/yellow stripe

Insulated Wire A conductor of electricity covered with a nonconducting material.

Jacket An extruded layer of insulation over a wire or group of cables.

Kilowatt (kW) A unit of power equal to one thousand watts.

Line Cord A cord, terminating in a plug at one end, used to connect equipment or appliances to a power unit.

N.A. North American color code on the inner conductors (black, white, green). See Inner Conductor Colors.

National Electrical Manufacturers Association (NEMA) Standard of wire, plug and cable specifications. See NEMA Plug & Receptical Configurations.

OD Abbreviation for outside diameter.

OHM Unit of electrical resistance. Resistance of a circuit in which a potential difference of one volt produces a current of one ampere.

PVC Polyvinyl chloride Compound used in thermoplastic SVT, SJT.

Power Supply Cord An attachment plug molded to a length of flexible cord. May also include a molded on strain relief, or terminations on the end opposite the plug.

Rated Voltage The maximum voltage at which an electric component can operate for extended periods without undo degradation or safety hazard.

Receptacle A contact device installed at the outlet for the connection of a single attachment plug.

Ribbed Outer jacket is striated with ribs.

Rip Cord Two or more insulated conductors in a parallel configuration which may be easily separated leaving the insulation of each conductor intact.

S Designated for heavy duty, rubber insulated portable cord. Stranded copper conductors with separator and individual rubber insulation. Two or more color coded conductors cabled with filler, wrapped with separator and rubber jacketed overall, 600V.

SEOW-A Extra hard service cord. Thermoplastic elastomer, oil resistant (TPE) construction Jacket. 600 volt, weather resistant for outdoor use.

SJ Designated for junior hard service, rubber insulated pendant or portable cord. Same construction as type S, but 300V.

SJEOW-A Extra hard service cord. Thermoplastic elastomer, oil resistant (TPE) construction jacket. 300 volt, weather resistant for outdoor use.

SJ0 Same as SJ but neoprene, oil resistant compound out jacket, 300V, 600C.

SJT Designated for junior hard service thermoplastic or rubber insulated conductors with overall thermoplastic outer jacket, 300V, 600C.

SJTO Same as SJT but oil resistant thermoplastic outer jacket.

SJTW A hard service cord. Thermoplastic constructed jacket. 300 volt, weather resistant for outdoor use.

S0 Designated for a 600 Volt senior service, oil resistant neoprene jacket cord. Same construction as type S except for neoprene jacket.

S0-W Heavy duty type 50-dual rated type W

SPT-1 Thermoplastic constructed, parallel jacketed, 300 volt, 2 or 3 conductor, 18 gauge.

SPT-2 Same as SPT-1 but heavier construction. 18-16 gauge.

SPT-3 Same as SPT-2 but heavier construction. 18-10 gauge.

ST Hard service cord, jacketed same as type S except all plastic construction, 600V 600 to 1050C.

STO Same as ST but with oil resistant thermoplastic outer jacket, 600V.

STW-A Extra hard service cord. Thermoplastic constructed jacket. 600 volt, weather resistant for outdoor use.

SV Designated for vacuum cleaner cord, two-or-three conductor, rubber insulated. Overall rubber jacket. For light duty in damp location. 300V, 600C.

SVT Same as SV except all plastic construction. With or without third conductor for grounding purposes only. 300V, 600-900C.

Shielded-Type Cable A cable in which the conductors are enclosed in a conducting envelope constructed so that substantially every point on the surface of the insulation is at ground potential or at some predetermined potential with respect to ground under normal operating conditions.

Strip To remove insulation from a cable.

Temperature Rating The maximum temperature at which the insulating material may be used in continuous operation without loss of its basic properties.

Terminal Any device attached to the conductor by crimping, soldering or welding.

Tensile Strength The pulling stress required to break a given specimen.

Thermoplastic Elastomer (TPE) A jacketed material which has many of the characteristics of rubber, as well as excellent electrical, mechanical and chemical properties.

Thermosetting A classification of resin which cures by chemical reaction when heated and, when cured, can not be resoftened by heating.

Tinned A silver-white, ductile metal used to coat copper conductors, especially when solder termination is to be used.

Tolerance The acceptable deviation from specification.

UL Underwriters Laboratories. This is a nonprofit independent organization that operates a listing service for electrical and electronic materials and equipment.

VW-1 A flammability rating established by Underwriters Laboratories for wires and cables that pass a specially designed vertical flame test, formerly designated FR-1.

Volt (V) Unit of electromotive force. It is the difference of potential required to make a current of one ampere flow through a resistance of one OHM.

Voltage The term most often used in place of electromotive force, potential, difference or voltage drop, to designate electric pressure that exists between two points and is capable of producing a flow of current when a closed circuit is connected between the two points.

Voltage Breakdown Test to determine maximum voltage of insulated wire before electrical current leakage through insulation. See hypot.

Voltage Rating The highest point that may be continuously applied to a wire or cord in conformance with standards or specifications.

W-A UL designation for outdoor-approved flexible cord.

Watt (W) Unit of power or work done at the rate of one joule per second or rate of work represented by current of one ampere under a pressure of one volt (volt-ampere).

Wire Gauge A system of numerical designations of wire sizes.

问询
Call
Email
💬
Text
💁
Chat
?
询价
我们可以帮助您?
我们可以帮助您?